Description

Electric valve is used for controlling the supply pressure to the units of automation, requiring prolonged exposure to the working environment.

 

When manufacturing and assembling of electric valves effective methods of quality control are used, such as: flaw and X-ray detection, magnaflux inspection, hydraulic and pneumatic testing, testing of air-helium mixture, etc.

Specifications

Technical characteristics Value
Operating pressure, mPa (kgf/cm2) 10-23 (100-230)
Operating environment air, nitrogen, helium, oxide
Temperature of operating environment, °С от -196 до +60
Pilot pressure, MPa (kgf/cm²) 17-23

(170-230)

Direct voltage, V no more than 32
Current, А no more than 0,5
Orifice diameter, mm 400
Material aluminum alloy
Mass, kg 2